Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Water Sci Technol ; 88(7): 1833-1846, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37830999

ABSTRACT

Illicit connections of wastewater to stormwater systems are the main drawback of separate sewer systems, as they lead to a direct discharge of untreated wastewater to the aquatic environment. Consequently, several inspection methods have been developed for detecting illicit connections. This study simultaneously applied several low- and high-tech methods for the detection of illicit connections in the same catchment (De Heuvel, the Netherlands). The methods included mesh wire screens for capturing coarse contamination, measurements of electroconductivity and temperature, sampling and quantification of Escherichia coli and extended-spectrum ß-lactamase-producing E. coli (ESBL-EC), DNA analysis via quantitative polymerase chain reaction for human-, dog-, and bird-specific fecal indicators, and distributed temperature sensing. Significant illicit connections could be identified using all methods. Nonetheless, hydraulic conditions and, predominantly, the sewage volume determine whether a misconnection can be detected by especially the low-tech methods. Using these results, the identified misconnections were repaired and biological and DNA analyses were repeated. Our results demonstrate that there were no changes in E. coli or ESBL-EC before and after mitigation, suggesting that these common markers of fecal contamination are not specific enough to evaluate the performance of mitigation efforts. However, a marked decrease in human wastewater markers (HF183) was observed.


Subject(s)
Environmental Monitoring , Wastewater , Animals , Humans , Dogs , Environmental Monitoring/methods , Escherichia coli/genetics , Sewage/analysis , Feces/chemistry , DNA
2.
Sci Total Environ ; 883: 163599, 2023 Jul 20.
Article in English | MEDLINE | ID: mdl-37100150

ABSTRACT

Despite high vaccination rates in the Netherlands, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continues to circulate. Longitudinal sewage surveillance was implemented along with the notification of cases as two parts of the surveillance pyramid to validate the use of sewage for surveillance, as an early warning tool, and to measure the effect of interventions. Sewage samples were collected from nine neighborhoods between September 2020 and November 2021. Comparative analysis and modeling were performed to understand the correlation between wastewater and case trends. Using high resolution sampling, normalization of wastewater SARS-CoV-2 concentrations, and 'normalization' of reported positive tests for testing delay and intensity, the incidence of reported positive tests could be modeled based on sewage data, and trends in both surveillance systems coincided. The high collinearity implied that high levels of viral shedding around the onset of disease largely determined SARS-CoV-2 levels in wastewater, and that the observed relationship was independent of variants of concern and vaccination levels. Sewage surveillance alongside a large-scale testing effort where 58 % of a municipality was tested, indicated a five-fold difference in the number of SARS-CoV-2-positive individuals and reported cases through standard testing. Where trends in reported positive cases were biased due to testing delay and testing behavior, wastewater surveillance can objectively display SARS-CoV-2 dynamics for both small and large locations and is sensitive enough to measure small variations in the number of infected individuals within or between neighborhoods. With the transition to a post-acute phase of the pandemic, sewage surveillance can help to keep track of re-emergence, but continued validation studies are needed to assess the predictive value of sewage surveillance with new variants. Our findings and model aid in interpreting SARS-CoV-2 surveillance data for public health decision-making and show its potential as one of the pillars of future surveillance of (re)emerging viruses.


Subject(s)
COVID-19 , Humans , COVID-19/epidemiology , SARS-CoV-2 , Wastewater , Wastewater-Based Epidemiological Monitoring , Sewage
3.
Sci Total Environ ; 873: 162209, 2023 May 15.
Article in English | MEDLINE | ID: mdl-36796689

ABSTRACT

Monitoring of SARS-CoV-2 in wastewater (WW) is a promising tool for epidemiological surveillance, correlating not only viral RNA levels with the infection dynamics within the population, but also to viral diversity. However, the complex mixture of viral lineages in WW samples makes tracking of specific variants or lineages circulating in the population a challenging task. We sequenced sewage samples of 9 WW-catchment areas within the city of Rotterdam, used specific signature mutations from individual SARS-CoV-2 lineages to estimate their relative abundances in WW and compared them against those observed in clinical genomic surveillance of infected individuals between September 2020 and December 2021. We showed that especially for dominant lineages, the median of the frequencies of signature mutations coincides with the occurrence of those lineages in Rotterdam's clinical genomic surveillance. This, along with digital droplet RT-PCR targeting signature mutations of specific variants of concern (VOCs), showed that several VOCs emerged, became dominant and were replaced by the next VOC in Rotterdam at different time points during the study. In addition, single nucleotide variant (SNV) analysis provided evidence that spatio-temporal clusters can also be discerned from WW samples. We were able to detect specific SNVs in sewage, including one resulting in the Q183H amino acid change in the Spike gene, that was not captured by clinical genomic surveillance. Our results highlight the potential use of WW samples for genomic surveillance, increasing the set of epidemiological tools to monitor SARS-CoV-2 diversity.


Subject(s)
COVID-19 , Wastewater , Humans , SARS-CoV-2/genetics , Sewage , COVID-19/epidemiology
4.
Sci Total Environ ; 865: 161196, 2023 Mar 20.
Article in English | MEDLINE | ID: mdl-36581271

ABSTRACT

Over the course of the Corona Virus Disease-19 (COVID-19) pandemic in 2020-2022, monitoring of the severe acute respiratory syndrome coronavirus 2 ribonucleic acid (SARS-CoV-2 RNA) in wastewater has rapidly evolved into a supplementary surveillance instrument for public health. Short term trends (2 weeks) are used as a basis for policy and decision making on measures for dealing with the pandemic. Normalisation is required to account for the dilution rate of the domestic wastewater that can strongly vary due to time- and location-dependent sewer inflow of runoff, industrial discharges and extraneous waters. The standard approach in sewage surveillance is normalisation using flow measurements, although flow based normalisation is not effective in case the wastewater volume sampled does not match the wastewater volume produced. In this paper, two alternative normalisation methods, using electrical conductivity and crAssphage have been studied and compared with the standard approach using flow measurements. For this, a total of 1116 24-h flow-proportional samples have been collected between September 2020 and August 2021 at nine monitoring locations. In addition, 221 stool samples have been analysed to determine the daily crAssphage load per person. Results show that, although crAssphage shedding rates per person vary greatly, on a population-level crAssphage loads per person per day were constant over time and similar for all catchments. Consequently, crAssphage can be used as a quantitative biomarker for populations above 5595 persons. Electrical conductivity is particularly suitable to determine dilution rates relative to dry weather flow concentrations. The overall conclusion is that flow normalisation is necessary to reliably determine short-term trends in virus circulation, and can be enhanced using crAssphage and/or electrical conductivity measurement as a quality check.


Subject(s)
COVID-19 , Wastewater , Humans , Sewage/analysis , SARS-CoV-2 , RNA, Viral , Water Pollution/analysis , Environmental Monitoring , Feces/chemistry , Water Microbiology , COVID-19/epidemiology
5.
Environ Sci Technol ; 55(15): 10432-10441, 2021 08 03.
Article in English | MEDLINE | ID: mdl-34264643

ABSTRACT

The shedding of pathogens by infected humans enables the use of sewage monitoring to conduct wastewater-based epidemiology (WBE). Although most WBE studies use data from large sewage treatment plants, timely data from smaller catchments are needed for targeted public health action. Traditional sampling methods, like autosamplers or grab sampling, are not conducive to quick ad hoc deployments and high-resolution monitoring at these smaller scales. This study develops and validates a cheap and easily deployable passive sampler unit, made from readily available consumables, with relevance to the COVID-19 pandemic but with broader use for WBE. We provide the first evidence that passive samplers can be used to detect SARS-CoV-2 in wastewater from populations with low prevalence of active COVID-19 infections (0.034 to 0.34 per 10,000), demonstrating their ability for early detection of infections at three different scales (lot, suburb, and city). A side by side evaluation of passive samplers (n = 245) and traditionally collected wastewater samples (n = 183) verified that the passive samplers were sensitive at detecting SARS-CoV-2 in wastewater. On all 33 days where we directly compared traditional and passive sampling techniques, at least one passive sampler was positive when the average SARS-CoV-2 concentration in the wastewater equaled or exceeded the quantification limit of 1.8 gene copies per mL (n = 7). Moreover, on 13 occasions where wastewater SARS-CoV-2 concentrations were less than 1.8 gene copies per mL, one or more passive samplers were positive. Finally, there was a statistically significant (p < 0.001) positive relationship between the concentrations of SARS-CoV-2 in wastewater and the levels found on the passive samplers, indicating that with further evaluation, these devices could yield semi-quantitative results in the future. Passive samplers have the potential for wide use in WBE with attractive feasibility attributes of cost, ease of deployment at small-scale locations, and continuous sampling of the wastewater. Further research will focus on the optimization of laboratory methods including elution and extraction and continued parallel deployment and evaluations in a variety of settings to inform optimal use in wastewater surveillance.


Subject(s)
COVID-19 , Wastewater , Cities , Humans , Pandemics , SARS-CoV-2
6.
Water Sci Technol ; 68(8): 1723-30, 2013.
Article in English | MEDLINE | ID: mdl-24185052

ABSTRACT

A major drawback of separate sewer systems is the occurrence of illicit connections: unintended sewer cross-connections that connect foul water outlets from residential or industrial premises to the storm water system and/or storm water outlets to the foul sewer system. The amount of unwanted storm water in foul sewer systems can be significant, resulting in a number of detrimental effects on the performance of the wastewater system. Efficient removal of storm water inflows into foul sewers requires knowledge of the exact locations of the inflows. This paper presents the use of distributed temperature sensing (DTS) monitoring data to localize illicit storm water inflows into foul sewer systems. Data results from two monitoring campaigns in foul sewer systems in the Netherlands and Germany are presented. For both areas a number of storm water inflow locations can be derived from the data. Storm water inflow can only be detected as long as the temperature of this inflow differs from the in-sewer temperatures prior to the event. Also, the in-sewer propagation of storm and wastewater can be monitored, enabling a detailed view on advection.


Subject(s)
Fiber Optic Technology/methods , Sewage , Germany , Netherlands , Rain , Temperature , Water Movements
7.
Water Sci Technol ; 68(3): 728-36, 2013.
Article in English | MEDLINE | ID: mdl-23925204

ABSTRACT

Modeling of integrated urban water systems (IUWS) has seen a rapid development in recent years. Models and software are available that describe the process dynamics in sewers, wastewater treatment plants (WWTPs), receiving water systems as well as at the interfaces between the submodels. Successful applications of integrated modeling are, however, relatively scarce. One of the reasons for this is the lack of high-quality monitoring data with the required spatial and temporal resolution and accuracy to calibrate and validate the integrated models, even though the state of the art of monitoring itself is no longer the limiting factor. This paper discusses the efforts to be able to meet the data requirements associated with integrated modeling and describes the methods applied to validate the monitoring data and to use submodels as software sensor to provide the necessary input for other submodels. The main conclusion of the paper is that state of the art monitoring is in principle sufficient to provide the data necessary to calibrate integrated models, but practical limitations resulting in incomplete data-sets hamper widespread application. In order to overcome these difficulties, redundancy of future monitoring networks should be increased and, at the same time, data handling (including data validation, mining and assimilation) should receive much more attention.


Subject(s)
Cities , Models, Theoretical , Rivers , Sanitary Engineering , Water Supply , Calibration , Environmental Monitoring , Reproducibility of Results , Sewage , Water Movements
SELECTION OF CITATIONS
SEARCH DETAIL
...